What Are the Best Armoured Doors Available?
Designed to withstand attempted break-in, fire and vandalism, armoured doors secure a building and its occupants. The level of protection varies according to the materials used and the standards applied by manufacturers. In the tailor-made, these devices are created according to your real needs to make your places of life real refuges.
Features of an armoured door
The choice of an armoured door begins with the type of manufacturing material. Among the most efficient, custom steel guarantees optimal quality. This metal stands out for its natural resistance to the risks of burglary. To this are added targeted assembly techniques such as welding to obtain non-formable panels. As well as light, curved and rigid profiles. In the case of fire protection, it is mainly the ei30 and ei60 armoured doors that are effective. These doors are able to hold smoke and toxic gases for 30 to 120 minutes. And for greater efficiency in the event of a fire, fire doors are equipped with an active safety device (DAS). This mechanism operates the opening or closing of the door according to its location vis-à-vis the starting point of the fire.
RC2, RC3 and RC4 burglar-resistance classes
In order to resist attempts at burglary, the safety doors apply EN 1627-28-29-30. These European regulations have made it possible to classify the level of resistance of doors to break-ins. For this purpose, doors include break-in carpenters designed to withstand a dynamic or static load. Manual burglaries are also taken into account. In the case of a RC2 class burglar-resistant door, the test lasts 15 minutes the door resists 3 minutes to an attempt at occasional burglary to the screwdriver or clamps or corners, used in medium residential spaces, Workshops and Shops. For a RC3 door, the test lasts 20 minutes and resists 5 minutes tool idem a RC2 + deer feet and manual drill. Used for higher-level residential areas, business sector, IT facilities and banks. A RC4 door, the resistance to percussion tools and saws used by professionals is 10 minutes. The test lasts 30 minutes used in the banking sector, army, …
Attention : for a test the laboratory receives the plans before test to study the door and these weak points, then to do the test it launches the chronometer, tries to force the door, if it does not see immediately that this is the solution it stops the chronometer checks the plans and the door to look for another point of attack re-launchs the chronometer and so on. Resistance time is considered to be 10 times multiplied by a burglar.
RC5 to RC7 armoured doors
To achieve their goal, burglars are getting better and better. From now on, they use drills and saw sets (slathers, swords). To cope with this, the RC5 armoured door must bring more resistance (15 minutes). In the RC6 resistance class, the level of safety is increased. To force the door, burglars use drills, angle grinders and jumping saws. But in any case, you get protection with a 20-minute resistance time.